Three Core Cables Cu/XLPE/PVC/SWA/PVC & Cu/XLPE/SWA/PVC
600/1000 V - THREE CORE
Copper Conductor
XLPE Insulated Steel Wire Armoured
PVC Sheathed Cables
(Cu/XLPE/PVC/SWA/PVC and Cu/XLPE/SWA/PVC)
Nominal Area of Conductor |
Maximum Conductor Resistance at 20°C |
Thickness of Insulation |
Thickness of Bedding |
Diameter of Armour Wire |
Thickness of Outer Sheath |
Approx. Overall Diameter |
Approx. Cable Weight |
Standard Packing Length |
Drum Size |
Approx. Gross Weight |
Extruded Bedding |
Lapped Bedding |
Extruded Bedding |
Lapped Bedding |
Extruded Bedding |
Lapped Bedding |
Extruded Bedding |
Lapped Bedding |
Sqmm |
Ohm/Km |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
Metre ±10% |
|
Kg |
1.5* |
12.1 |
0.7 |
0.8 |
- |
0.9 |
1.3 |
13.3 |
- |
330 |
- |
1000 |
D-10 |
390 |
- |
1.5 |
12.1 |
0.7 |
0.8 |
- |
0.9 |
1.3 |
13.7 |
- |
350 |
- |
1000 |
D-10 |
410 |
- |
2.5* |
7.41 |
0.7 |
0.8 |
- |
0.9 |
1.4 |
14.4 |
- |
390 |
- |
1000 |
D-10 |
450 |
- |
2.5 |
7.41 |
0.7 |
0.8 |
- |
0.9 |
1.4 |
14.8 |
- |
415 |
- |
1000 |
D-10 |
475 |
- |
|
4 |
4.61 |
0.7 |
0.8 |
- |
0.9 |
1.4 |
15.9 |
- |
490 |
- |
1000 |
D-11 |
590 |
- |
6 |
3.08 |
0.7 |
0.8 |
- |
0.9 |
1.4 |
17.2 |
- |
580 |
- |
1000 |
D-12 |
690 |
- |
10 |
1.83 |
0.7 |
0.8 |
- |
1.25 |
1.5 |
19.6 |
- |
850 |
- |
1000 |
D-12 |
960 |
- |
|
16 |
1.15 |
0.7 |
0.8 |
- |
1.25 |
1.6 |
22.2 |
- |
1110 |
- |
1000 |
D-14 |
1260 |
- |
25 |
0.727 |
0.9 |
1.0 |
0.8 |
1.6 |
1.7 |
24.3 |
23.2 |
1520 |
1420 |
500 |
D-11 |
870 |
810 |
35 |
0.524 |
0.9 |
1.0 |
0.8 |
1.6 |
1.8 |
26.9 |
25.8 |
1910 |
1790 |
500 |
D-12 |
1065 |
1010 |
|
50 |
0.387 |
1.0 |
1.0 |
0.8 |
1.6 |
1.8 |
30.1 |
29.0 |
2400 |
2250 |
500 |
D-12 |
1350 |
1230 |
70 |
0.268 |
1.1 |
1.0 |
0.8 |
1.6 |
1.9 |
32.8 |
31.7 |
3100 |
2950 |
500 |
D-14 |
1700 |
1630 |
95 |
0.193 |
1.1 |
1.2 |
0.8 |
2.0 |
2.1 |
38.2 |
36.7 |
4310 |
4060 |
500 |
D-16 |
2400 |
2270 |
|
120 |
0.153 |
1.2 |
1.2 |
0.8 |
2.0 |
2.2 |
41.8 |
40.3 |
5170 |
4920 |
500 |
D-18 |
2830 |
2700 |
150 |
0.124 |
1.4 |
1.4 |
0.8 |
2.5 |
2.3 |
46.4 |
44.5 |
6620 |
6290 |
500 |
D-18 |
3550 |
3390 |
185 |
0.0991 |
1.6 |
1.4 |
0.8 |
2.5 |
2.4 |
50.8 |
48.9 |
7860 |
7510 |
250 |
D-18 |
2210 |
2090 |
|
240 |
0.0754 |
1.7 |
1.4 |
0.8 |
2.5 |
2.6 |
56.9 |
55.0 |
9810 |
9410 |
250 |
D-18 |
2690 |
2590 |
300 |
0.0601 |
1.8 |
1.6 |
0.8 |
2.5 |
2.7 |
61.8 |
59.5 |
11910 |
11430 |
250 |
D-18 |
3220 |
3100 |
400 |
0.0470 |
2.0 |
1.6 |
0.8 |
2.5 |
2.9 |
69.2 |
66.9 |
14910 |
14330 |
200 |
D-19 |
3300 |
3110 |
* Circular solid conductors (Class 1).
Conductors including 16 Sqmm circular stranded (Class 2).
25 Sqmm and above shaped stranded conductors (Class 2 ).
Cables conform to BS 5467 and generally to IEC 60502-1.
Drum size given above are for cables with extruded bedding