Three Core Cables Cu/XLPE/PVC/SWA/PVC & Cu/XLPE/SWA/PVC
600/1000 V - THREE CORE
Copper Conductor
XLPE Insulated Steel Wire Armoured
PVC Sheathed Cables
(Cu/XLPE/PVC/SWA/PVC and Cu/XLPE/SWA/PVC)
Nominal Area of Conductor |
Maximum Conductor Resistance at 20°C |
Thickness of Insulation |
Thickness of Bedding |
Diameter of Armour Wire |
Thickness of Outer Sheath |
Approx. Overall Diameter |
Approx. Cable Weight |
Standard Packing Length |
Drum Size |
Approx. Gross Weight |
Extruded Bedding |
Lapped Bedding |
Extruded Bedding |
Lapped Bedding |
Extruded Bedding |
Lapped Bedding |
Extruded Bedding |
Lapped Bedding |
Sqmm |
Ohm/Km |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
Metre ±10% |
|
KG |
1.5* |
12.1 |
0.7 |
1.0 |
- |
0.9 |
1.8 |
14.7 |
- |
380 |
- |
1000 |
D-10 |
440 |
- |
1.5 |
12.1 |
0.7 |
1.0 |
- |
0.9 |
1.8 |
15.1 |
- |
400 |
- |
1000 |
D-10 |
460 |
- |
2.5* |
7.41 |
0.7 |
1.0 |
- |
0.9 |
1.8 |
15.6 |
- |
440 |
- |
1000 |
D-10 |
500 |
- |
2.5 |
7.41 |
0.7 |
1.0 |
- |
0.9 |
1.8 |
16.0 |
- |
460 |
- |
1000 |
D-11 |
560 |
- |
|
4 |
4.61 |
0.7 |
1.0 |
- |
0.9 |
1.8 |
17.1 |
- |
540 |
- |
1000 |
D-11 |
640 |
- |
6 |
3.08 |
0.7 |
1.0 |
- |
0.9 |
1.8 |
18.4 |
- |
640 |
- |
1000 |
D-12 |
750 |
- |
10 |
1.83 |
0.7 |
1.0 |
- |
1.25 |
1.8 |
21.2 |
- |
940 |
- |
1000 |
D-14 |
1090 |
- |
|
16 |
1.15 |
0.7 |
1.0 |
- |
1.25 |
1.8 |
23.4 |
- |
1200 |
- |
1000 |
D-14 |
1350 |
- |
25 |
0.727 |
0.9 |
1.0 |
0.8 |
1.6 |
1.8 |
24.5 |
23.4 |
1520 |
1445 |
500 |
D-11 |
875 |
825 |
35 |
0.524 |
0.9 |
1.0 |
0.8 |
1.6 |
1.8 |
26.9 |
25.8 |
1910 |
1815 |
500 |
D-12 |
1065 |
1020 |
|
50 |
0.387 |
1.0 |
1.0 |
0.8 |
1.6 |
1.9 |
30.3 |
29.2 |
2420 |
2275 |
500 |
D-12 |
1360 |
1245 |
70 |
0.268 |
1.1 |
1.2 |
0.8 |
2.0 |
2.0 |
34.2 |
32.7 |
3300 |
3165 |
500 |
D-16 |
1860 |
1795 |
95 |
0.193 |
1.1 |
1.2 |
0.8 |
2.0 |
2.2 |
38.4 |
36.9 |
4330 |
4075 |
500 |
D-16 |
2410 |
2250 |
|
120 |
0.153 |
1.2 |
1.2 |
0.8 |
2.0 |
2.3 |
42.0 |
40.5 |
5190 |
4965 |
500 |
D-18 |
2840 |
2725 |
150 |
0.124 |
1.4 |
1.4 |
0.8 |
2.5 |
2.5 |
46.8 |
44.9 |
6660 |
6330 |
500 |
D-18 |
3560 |
3405 |
185 |
0.0991 |
1.6 |
1.4 |
0.8 |
2.5 |
2.6 |
51.2 |
49.3 |
7900 |
7550 |
250 |
D-18 |
2220 |
2130 |
|
240 |
0.0754 |
1.7 |
1.6 |
0.8 |
2.5 |
2.8 |
57.7 |
55.4 |
9950 |
9490 |
250 |
D-18 |
2730 |
2615 |
300 |
0.0601 |
1.8 |
1.6 |
0.8 |
2.5 |
3.0 |
62.4 |
60.1 |
12000 |
11495 |
250 |
D-18 |
3240 |
3115 |
400 |
0.0470 |
2.0 |
1.6 |
0.8 |
2.5 |
3.2 |
69.8 |
67.5 |
15020 |
14345 |
200 |
D-19 |
3325 |
3190 |
|
500 |
0.0366 |
2.2 |
1.8 |
0.8 |
3.15 |
3.5 |
76.9 |
76.1 |
18900 |
18320 |
200 |
D-19 |
4100 |
3985 |
* Circular solid conductors (Class 1).
Conductors including 16 Sqmm circular stranded (Class 2).
25 Sqmm and above shaped stranded conductors (Class 2 ).
Cables conform to IEC 60502-1.
Drum size given above are for cables with extruded bedding